Concrete Moisture Test Starter Kit+ with Rapid RH® L6

USD $793.00

• 5 Smart Sensors.
• 1 Total Reader
• 2 Smart Loggers
• 1 SDS Masonry drill bit
• Read more product details

Clear
Learn More

Product Description

Your smart device will detect any Wagner Meters wireless device that features Bluetooth connectivity such as the Smart Logger or Orion 950 Smart Pinless Wood Moisture Meter, and perform the pairing procedure automatically. There is nothing you need to do, the devices do the work for you.

The Concrete Moisture Test Starter Kit+ with Rapid RH® L6 includes the following:

  • 5 ea. L6 Smart Sensors
  • 1 ea. Total Reader® with Touch-n-Sense™ Technology
  • 2 Smart Logger™ Ambient Temperature and Humidity Recorders
  • 1 ea. Insertion Tool
  • 10 ea. Extensions
  • 5 ea. Protective Caps with Rubber Plugs and Butyl Gasket
  • 5 ea. Stainless Steel Covers
  • 1 ea. ¾” SDS Masonry Drill Bit
  • 1 ea. Wire Cleaning Brush
  • 1 ea. Vacuum Attachment
  • Certificate of Calibration
  • Floor Map
  • Instruction Manual
  • Carrying Case
  • One CR1/3N Battery for the Total Reader

Rapid RH® L6 sensors feature a customized version of the SHT35 humidity sensor from Sensirion that has a +/-2% accuracy tolerance at 50% and 90% relative humidity (RH). This important aspect of the L6 concrete RH testing system puts it in direct compliance with ASTM F2170. Standard SHT35 humidity sensors, found in other concrete RH test systems, start to deviate from the +/-2% tolerance at RH levels as low as 50%.

Each Rapid RH® Starter Kit is carried within a water-tight and dust-proof hard case built to military specifications. ATA 300 rated and 2.8 times stronger than the competition, the iSeries hard cases from SKB are made in the USA and built to meet or exceed MIL-STD-810G, MIL-C-41503, DEF-STAN 81-41, and IP67 standards.

The Most Innovative Product (MIP) is awarded to concrete-related products submitted from around the world and voted upon by industry professionals during the annual World of Concrete event. Categories range from Business and Industry to Materials.

Questions? Give us a call: (541) 291-5123

 

Downloads

  

Manuals

  Rapid RH® L6 Manual
  Rapid RH® L6 eBrochure
  Rapid RH® L6 eBrochure – ESPAÑOL
  How to use the DataMaster™ L6 App

DataMaster™ L6

Datamaster Icon
The DataMaster™ L6 improves upon the incredible utility of the DataMaster 5.0 app with streamlined navigation to information and reporting functions making your concrete slab relative humidity (RH) testing faster and easier than before. The DataMaster L6 app connects via Bluetooth® to the Rapid RH® Total Reader® for a completely wireless system of reading, recording, and reporting your concrete slab moisture test data. The DataMaster L6 takes advantage of an unbroken stream of data to give you the highest level of data integrity.

  • Capture, assemble, and email all data necessary to adhere to the ASTM F2170 standard.
  • Ensure the integrity of your critical Rapid RH data from sensors and email “READ ONLY” reports.
  • Link all recorded data to your job site’s sensor locations with a mapping function.
  • Input job metadata such as job name, address, and hole depth.
  • Add photos, audio memos, and text notes to your job info.
  • Print reports directly from your smart device.
  • Easily upload your job data to the F2170reports.com website.

Rapid RH L6 now includes automated data logger technology. The DataGrabber with Bluetooth, a self-contained device designed to fit inside a Rapid RH L6 Smart Sensor, will periodically engage the sensor to store time-stamped concrete temperature and RH readings according to the time interval set by the user. The DataGrabber with Bluetooth connects directly to the free DataMaster L6 app for wireless download of sensor readings and programming of sensor reading intervals. A smaller version of the DataGrabber is configured by contacting the Rapid RH Total Reader to connect with the DataMaster L6 app. While connected, with either version of the DataGrabber, you can also download all previous time-stamped concrete RH and temperature readings directly from the L6 Smart Sensor.

The DataMaster L6 app is designed to be used only with Rapid RH L6 Smart Sensors, Rapid RH DataGrabbers, and the Rapid RH Total Reader for fast, accurate, and reliable RH testing.

Datamaster Apple App  Datamaster Android App

Smart Logger™ app

Wagner Meters Smart Logger app available in the Apple iTunes and Google Play Store
The Wagner Meters Smart Logger™ app connects with the (required) Smart Logger device via Bluetooth® 4.0 connection and enables you to monitor and record ambient relative humidity and temperature data in real time from up to 300 devices for up to 300 days. The app’s user-friendly interface allows you to program reading intervals, set alarm ranges, and email up to 12,000 data reports directly from the job site.

The only way to be sure service conditions remain is through constant observation and recording. The Wagner Meters Smart Logger monitor device and the Smart Logger app are your eyes on the job site 24 hours a day.

  • Save time and money by reducing the need for excess job site visits to monitor ambient conditions.
  • Reduce your liability and avoid “the blame game” with documented monitoring of job site conditions.
  • Maintain your great reputation by using the latest technology to ensure successful outcomes.

Smart Logger Apple AppSmart Logger Android App

Videos

Rapid RH L6: How to Install (The Right Way)

Why is 40% the Magic Number for Concrete Moisture Testing?

How To Remove Battery

Making Flooring Professional’s Life Easier [Best Practices]

DataMaster L6 Tutorial

Concrete Moisture Testing the Correct Way

FAQs

What does equilibration mean when talking about moisture testing?
Equilibration, or when moisture readings in a concrete slab stabilize and stop changing, occurs when a drilled hole achieves thermal and moisture equilibrium. For the accuracy of the readings, it is necessary to wait until equilibrium is restored after drilling. In most cases, the Rapid RH® Smart Sensor will be within 3-5% of the final reading one hour after installation. Follow ASTM F2170 procedures pertaining to equilibration time. Once equilibration is achieved, future readings can be taken instantaneously with the Rapid RH® Total Reader® or Smart Reader.

What is Touch-n-Sense™ Technology (for L6)?
Touch-n-Sense™ is our patent-pending technology, integrated into the Rapid RH® Total Reader to enable it to automatically take a reading when placed in contact with the Rapid RH® L6 Smart Sensors. Once the bottom of the Total Reader makes contact with the Smart Sensor, it takes a reading. The Total Reader holds the reading for 5 minutes, even when removed from the test hole. It also sends send readings to your mobile device via Bluetooth®. It’s just that easy.

How long will the display on the Rapid RH® Total Reader stay on?
The display on the Rapid RH® Total Reader will toggle between RH (%) and temperature readings for a period of five minutes before it turns itself off.

Does my Rapid RH® Total Reader need to be calibrated periodically?
No. Each Rapid RH Smart Sensor has an embedded calibration from the factory.* The Total Reader simply displays what the Smart Sensor tells it. Therefore, no calibration is necessary.

Reviews

There are no reviews yet.

Be the first to review “Concrete Moisture Test Starter Kit+ with Rapid RH® L6”

This site uses Akismet to reduce spam. Learn how your comment data is processed.